Hiden Analytical Limited

+44 (0) 1925 445 225 http://www.HidenAnalytical.com

Request Information

New Hiden Brochure Details MS Vacuum Process Monitors

Hiden Analytical release their new brochure featuring the full range of quadrupole mass spectrometers designed specifically for vacuum process monitoring. Systems cover the full
pressure range from UHV (background species, leak detection) through to the millibar regime (process monitoring, control and protection).

The higher pressure regimes are addressed by the Hiden HPR-30 system. Together with integrated dry vacuum pumping and overpressure protection the system is configured to mount
directly to the process chamber. Mounted on the high-stability mobile monitor pillar the system is readily adjustable both vertically and horizontally and is easily moved to alternative process
system sampling points. The 300 amu mass range is applicable to the majority of process environments, with alternative mass range options available for specialised applications.
 
At lower pressures below 5x10-3 millibar the dual-mode Hiden HMT residual gas analyser
(RGA) utilizes the Faraday detector for high pressure operation yet operates at low pressure to UHV with electron multiplier detection and full-sensitivity to give partial pressure detection to 2x10-13  millibar, a dynamic range of more than 10 decades. The HALO and HAL RGA series are optimised for operation at the lower pressure regimes with extensive mass range options up to 1000 amu and minimum detectable partial pressures down to 5X10-15 millibar. All systems can be process integrated to combine process (temperature for example) and mass spectrometer data in a common spectral presentation.

ima


For full details on this or any other Hiden Products contact Hiden Analytical at info@hiden.co.uk or visit the main website: www.HidenAnalytical.com.

What’s new

  • btr

    APSI mode simplifies MS spectral analysis

    News | 21 Dec 2017

    Analysis of gaseous species by quadrupole mass spectrometry involves ionisation of the molecular species most typically by the electron bombardment technique, the ionisation process creatingfragmentation ions additionally to the parent ion. Spectral interpretation can then be compromised by spectral interference in some gaseous mixtures.

  • ima

    New Hiden Brochure Details MS Vacuum Process Monitors

    News | 21 Dec 2017

    Hiden Analytical release their new brochure featuring the full range of quadrupole mass spectrometers designed specifically for vacuum process monitoring. Systems cover the fullpressure range from UHV (background species, leak detection) through to the millibar regime (process monitoring, control and protection).

  • 4

    Diagnostic Tools for Atomic Layer Deposition

    News | 21 Dec 2017

    Hiden Analytical offers a range of mass spectrometer products of special significance to  the process and post-process stages of atomic layer deposition (ALD) and evaluation.

  • 3

    Microreactor/MS System for Thermal Process Characterisation

    News | 21 Dec 2017

    The Hiden CATLAB-PCS combined microreactor and mass spectrometer system is purpose designed for the characterisation and evaluation of catalysts, for temperature programmed desorption and reaction testing, and for general thermal studies.

  • 2

    Hiden ExQ Gas Analysers for TGA/TA Analytics

    Products | 21 Dec 2017

    The Hiden ExQ quantitative gas analyser is a new multi-featured and compact massspectrometer system…