Hiden Analytical Limited

+44 (0) 1925 445 225 http://www.HidenAnalytical.com

Request Information

The Hiden Transient-MS analyser for fast gas processes

The Hiden HPR-20 QIC TMS Transient Mass Spectrometer system is specifically configured for analysis of fast gas reaction processes operating through a broad pressure regime from 2 bar down to a low 100 mbar. Applications include flash-heating studies, respiratory analysis, sorption/desorption rate monitoring and assessment of gas/surface interaction kinetics.

The compact benchtop system features the Hiden 3F/PIC series triple-filter quadrupole for optimum sensitivity, species identification and contamination resistance. The fast digital detector system provides a wide dynamic range through 7 continuous decades with a sampling rate capability in excess of 500 data points per second. Individual gaseous species may be selected and monitored within 6 milliseconds, with pulse profile resolution(5% to 95% peak height) in just 60 milliseconds. Sampling from the process is via an inert quartz-lined heated interface, process gases being exposed to quartz and platinum surfaces prior to analysis to maintain sample integrity. The APSI soft ionisation operating mode minimises ion fragmentation for simplification of complex mass spectra.

The Transient system monitors gases and vapours with molecular weights to 300amu with higher mass ranges available for specialised applications, and systems include provision for import of two external process parameters, temperature and/or weight for example, for integration with the mass spectral data.

Hpr 20 qic tms transient ms

HPR-20 QIC TMS Transient MS

 

Hap0146 argon aliquots in helium stream image

Argon aliquots in helium stream



For further information on this or any other Hiden Analytical products contact Hiden Analytical at info@hiden.co.uk or visit the main website at www.HidenAnalytical.com.

What’s new

  • Image for hiden

    Hiden Analytical Gas Analysers at Pittcon 2017 Visit us on Booth 1722

    News | 23 Feb 2017

    Hiden Analytical are exhibiting their latest laboratory gas analysers at Pittcon 2017, 5th - 9th March, Chicago, Illinois, USA, where Hiden will feature their latest HPR-20 systems for direct real time analysis, quantification and control of gas related processes ranging in pressure from 100 mbar to 50 bar.

  • Hiden logo

    Hiden Analytical 35 Year Anniversary

    News | 15 Feb 2017

    2017 marks Hiden Analytical’s 35th year of continuous and independent operation in the fields of mass spectrometry and gas sorption science, independent operation creating a unique and successful company culture orientated both to the researcher and to the process industry.

  • Hiden logo

    New Hiden CATLAB Microreactor/MS Brochure

    News | 9 Dec 2016

    The new brochure details the Hiden CATLAB-PCS combined microreactor and mass spectrometer system, purpose designed for the characterisation and evaluation of catalysts together with general thermal studies including temperature programmed desorption and reaction testing

  • Hiden logo

    Gas Composition Measurement in Aqueous Media

    News | 1 Nov 2016

    The Hiden HPR-40 DSA mass spectrometer system was introduced specifically for measurement of gases and vapours in aqueous media.

  • Hiden logo

    New Hiden ExQ gas analysis system

    News | 29 Sep 2016

    The Hiden ExQ gas analysis system features direct real time multi-species analysis and quantification of gas and vapour related processes.

Search all our content