Hiden Analytical Limited

+44 (0) 1925 445 225 http://www.HidenAnalytical.com

Request Information

APSI mode simplifies MS spectral analysis

Analysis of gaseous species by quadrupole mass spectrometry involves ionisation of the molecular species most typically by the electron bombardment technique, the ionisation process creating
fragmentation ions additionally to the parent ion. Spectral interpretation can then be compromised by spectral interference in some gaseous mixtures.

Hiden Analytical introduce the APSI(Appearance Potential Soft Ionisation)  mode to their full range of gas analysis systems to enable reduction of the fragmentation ion effect for many species, resulting in enhanced spectral purity to simplify spectral interpretation. Each molecular species has a specific ionisation energy threshold at which the parent ion is formed, higher electron energy then generating fragmentation of the ion. The Hiden APSI mode enables the user to set discreet ion energies from as low as 4eV for each individual mass channel to selectively identify parent ions and to minimise generation of fragmentation ions.

Application examples include identification of deuterium in helium (both at m/z 4), ammonia in the presence of water vapour (suppression of the OH ion at m/z 17), part-per-million water levels in
argon (suppression of argon isotope ion 36A at m/z 18). The 3D profile scan presentation displays selected multiple mass channels with peak intensity v. electron energy to rapidly establish thebeneficial and individual energy levels for each selected mass channel.

btr

Direct measurement of ammonia in water with Soft Ionisation

For full details on this or any other Hiden Products contact Hiden Analytical at info@hiden.co.uk or visit the main website: www.HidenAnalytical.com.

What’s new

  • btr

    APSI mode simplifies MS spectral analysis

    News | 21 Dec 2017

    Analysis of gaseous species by quadrupole mass spectrometry involves ionisation of the molecular species most typically by the electron bombardment technique, the ionisation process creatingfragmentation ions additionally to the parent ion. Spectral interpretation can then be compromised by spectral interference in some gaseous mixtures.

  • ima

    New Hiden Brochure Details MS Vacuum Process Monitors

    News | 21 Dec 2017

    Hiden Analytical release their new brochure featuring the full range of quadrupole mass spectrometers designed specifically for vacuum process monitoring. Systems cover the fullpressure range from UHV (background species, leak detection) through to the millibar regime (process monitoring, control and protection).

  • 4

    Diagnostic Tools for Atomic Layer Deposition

    News | 21 Dec 2017

    Hiden Analytical offers a range of mass spectrometer products of special significance to  the process and post-process stages of atomic layer deposition (ALD) and evaluation.

  • 3

    Microreactor/MS System for Thermal Process Characterisation

    News | 21 Dec 2017

    The Hiden CATLAB-PCS combined microreactor and mass spectrometer system is purpose designed for the characterisation and evaluation of catalysts, for temperature programmed desorption and reaction testing, and for general thermal studies.

  • 2

    Hiden ExQ Gas Analysers for TGA/TA Analytics

    Products | 21 Dec 2017

    The Hiden ExQ quantitative gas analyser is a new multi-featured and compact massspectrometer system…

Search all our content